r
| The
Air separation plant shown above deploys a four bed arrangement and two
stage adsorption to achieve the results shown in the following
table. Energy is also saved by pre-cooling the process air
with an evaporative water chiller employing waste nitrogen from the air
separation plant. The chiller operates in a closed loop circuit
with a direct contact aftercooler (DCAC) and only requires a small
amount of water for make-up. The Chemical Design proprietary four
bed design allows for a continuous flow of regeneration gas thus
eliminating a sharp peak demand and the need for a heat
accumulator. The electric regen heater is 50% of it's normal two
bed size and thermal cycling stress is greatly reduced. |
|
|
|
Feed |
Product |
| Rate:
117,000 SCFH |
Moisture:
<1 vppm |
| Pressure: 100
psia |
CO2: <1
vppm |
| Temperature: 95oF |
Temperature: 63oF |
| |
|
|
|
2004 Chemical
Design, Inc. Site Disclaimer
|