Home Systems Custom Engineering Services Customers About Contact Us Downloads


 

 

 

 

 

 

 

 
r

Front End Purification System

 

The Air separation plant shown above deploys a four bed arrangement and two stage adsorption to achieve the results shown in the following table.  Energy is also saved by pre-cooling the process air with an evaporative water chiller employing waste nitrogen from the air separation plant.  The chiller operates in a closed loop circuit with a direct contact aftercooler (DCAC) and only requires a small amount of water for make-up.  The Chemical Design proprietary four bed design allows for a continuous flow of regeneration gas thus eliminating a sharp peak demand and the need for a heat accumulator.  The electric regen heater is 50% of it's normal two bed size and thermal cycling stress is greatly reduced. 

 

Feed Product
Rate:  117,000 SCFH Moisture: <1 vppm
Pressure: 100 psia CO2: <1 vppm
Temperature: 95o Temperature: 63o
   

2004 Chemical Design, Inc. Site Disclaimer